Configuration Requirements
Road Sim card (optional), EVSE ID, configuration manual for the installer and registration manual for the owner of the charging station
Configuration device: laptop
Micro-USB cable capable of Datatransfer
Follow the steps
Step 1:Plug in the Micro-USB in the controller’s config port. The GLB+ only has one controller (see picture below)
The Twin+ & LS4 has 2 controllers (see picture below)
Step 2:Once plugged into the controller open a web browser and navigate to one of the following IP addresses:
New Interface (white background) - refer to page 3
192.168.123.123
Legacy Interface (red background) - refer to page 5
Note, if you can’t access the legacy interface with above IP address please try:
GLB+
192.168.123.123/operator/operator
TWIN+, LS4:
192.168.123.123:81/operator/operator Outlet 1
192.168.123.123:82/operator/operator Outlet 2
192.168.123.123/legacy/operator/operator
Login Credentials:
Username: operator
Password: cherry_zone or yellow_zone
Step 3:After logging into the charge controller, follow these steps:
Navigate to the Backend menu (wait for the page to fully load) and Connection
Select the Connection Type
No backend = No connection to an operator
GSM = 4G SIM card
Ethernet = LAN
USB = Not in use
WLAN = Not in use
Fill in the charger´s CBID in the corresponding field OCPP ChargeBoxIdentity (ChargePointID) Note: This is a unique ID-number that differs from various CPO’s, and therefore it needs to be provided by the backend operator you’re configuring the charger to connect to.
3. Set the OCPP Mode to the latest version, most current is OCPP-J 1.6
4.Fill in the WebSockets JSON OCPP URL ws://ocpp.road.io/<provider-slug> provided by your backend operator.
5. Press “Save” to apply the changes. (The bar is visible at the bottom of the scree
6. Click “Restart”, and when the “Restart Charger” appears, confirm by pressing “Restart” again.
After the above operation (s) are done the charger will restart. Wait until the chargers LED’s displays a green light and log back into the web interface. Use the login credentials:
• Username: operator
• Password: cherry_zone or yellow_zone
Once logged in, navigate to the “Diagnostics” menu and verify that the charger shows “Connected” under “Connection State (Backend)