Configuration Requirements
EVSE ID, configuration manual for the installer and registration manual for the owner of the charging station
Installation manual Scame BE-T
Configuration device: laptop, smartphone or tablet
Ethernet cable or Wi-Fi Hotspot
Follow the steps
Step 1: Use the Installation manual of the Scame BE-T to savely complete the installation of the charger.
Step 2: Connect the master station to your configuration device via ethernet or connect the station to a local network via Wi-Fi.
Step 3: Connect the RS485 serial line from the satellite stations to the master station (up to 16 charging points).
Step 4: Enter the following IP address in your web browser (Internet Explorer, Google Chrome, Firefox,…): 192.168.30.126
Step 5: Login to the server by using the following credentials:
Username: admin
Password: gsroot
Step 6: Navigate to the Settings menu in the server to change the configuration of the station.
Step 7: Open the Network Setup menu and configure the right parameters to connect the station to the network. The control system will be connected to the IP-address entered in this menu.
Step 8: Select OCPP 1.6 JSON in the OCPP Type Selector menu.
Step 9: Open the OCPP 1.6 Setup menu and enter the following values:
OCPP Enabled: ‘Enable OCPP’
WebSocket SSL: ‘Disable WebSocket SSL’
Central Station IP Address: ws://ocpp.road.io
Central Station TCP Port: 80
Central Station Path: /<provider-slug>
Charge Box Identity: ‘Enter the unique serial number of the charging station’
SIM Card Serial Number (ICCID): ‘Leave empty’
SIM Card PIN (IMSI): ‘Leave empty’
Step 10: Click on Save and reboot the station.